Harry High Performance House - Anglesea
Sustainability & Performance Specs
Project type: New Build
Performance: Passive House low energy)
Heating demand: 17.6kWh
Cooling demand: 9kWh
Airtightness: 0.58ACH
Ceiling/roof R values: 240mm Timber rafters & counter rafter with Earthwool + 40mm wood fibre
R5.0 + R2.0 + R1.0 = R8.0
Floor: R5 Batts to 240mm floor joists. R3 XPS Decoupled slab
Wall assembly: 140mm Insulated timber stud frame, plus 40mm wood fibre insulation
R4.0+R1.0 = R5.0
Internal airtight vapour permeable membrane: ProClima vapour membrane
Windows & doors: Doors: Binq Lift-n-Slide & IV68 front door, double glazed. Windows: Tilt-turn, triple glazed
MHRV: Zehnder Comfoair CA200, via FANTECH
NatHERS: 7.4 Stars
Orientation/shading/eaves: North: wide & high eaves East: nil, minimal windows West: no windows
South: eave
Heat pump hot water: Reclaim Heat pump hot water
Solar PV: 6.6kW solar
Battery: 13.5kWh Tesla Power Wall
Water: 15,000 L rainwater tank
Size: 138m2 + garage
Bushfire resilience: Bushfire rating: BAL 29. Bushfire species timbers: Blackbutt Windows & doors: 6mm toughened glass Cladding: 9mm fibre cement cladding Stainless steel mesh to all gaps and cavities
Builder: owner builder